Hanna Optical Dissolved Oxygen Meter Kit
Product Code: #HI98198
The Hanna HI 98198 Optical Dissolved Oxygen Meter Kit produces readings you can rely on. It's made from highly durable materials and advanced technologies to provide you with long-lasting accuracy. It can even log up to 4,000 individual readings. Plus, the DO meter comes with a probe and various accessories and solutions.
Features:
- Measures the concentration of dissolved oxygen in water
- Requires no membranes, no filling solution and no warm-up time
- Optical DO technology ensures stable, accurate readings
- IP67-rated body is rugged and waterproof
- GLP data: date, time, pressure, calibrated value, temperature and salinity value of the last calibration
- Data logging function can save up to 4,000 readings
- USB-C port makes transferring data easy
- Probe is made with an IP68-rated ABS body and stainless-steel guard to resist water and dust
- Smart Cap™ technology with built-in RFID reader
- Includes assortment of accessories and solutions
- Automatic shutoff modes: 5, 10, 30 and 60 minutes or disabled
- Applications Saltwater, Freshwater
Included:
-
Meter
-
HI 764113 Probe
-
Smart Cap™ with O-Ring
-
Bicomponent Zero Oxygen Solution
-
Calibration/Storage Vessel
-
2 x Plastic Beakers
-
Syringe with Silicone Grease
-
Lens Wipe
-
4 x 1.5 V AA Batteries
-
Instruction Manual
-
Meter Quality Certificate
-
Probe Quality Certificate
-
Cap Quality Certificate
-
USB Type A to C Cable
-
Carrying Case
DO Range | 0 to 50 mg/L, 0 to 500% saturation |
DO Resolution | 0.01 mg/L, 0.1% saturation |
DO Accuracy | 1.5% of reading ±0.01mg/L for 0 to 20 mg/L; 5% of reading for 20 to 50 mg/L; 1.5% of reading ±0.1% for 0 to 200%; 5% of reading for 200 to 500% |
DO Calibration | Manual or automatic (1 or 2 points) |
DO Temperature Compensation | Automatic from 23 to 122°F (-5 to 50°C) |
Barometric Pressure Compensation | Single point anywhere within pressure range |
Salinity Compensation | Automatic from 0 to 70 PSU (manually set) |
Altitude Compensation | Automatic from 420 to 850 mmHg |
Temperature Range | 23 to 122°F (-5 to 50°C) |
Temperature Resolution | 0.1° |
Temperature Accuracy | ±0.4°F (±0.3°C) |
Display | Backlit LCD |
AutoEnd | Yes |
Battery Life | ~200 hours of continuous use without backlight; ~50 hours with backlight |
Environment | 32 to 122°F (0 to 50°C); 100% RH max |
Product Length | 7.3" (185 mm); 13' (4 m) probe cable |
Product Width | 3.6" (93 mm) |
Product Height | 1.4" (35.2 mm) |
Product Weight | 15.9 oz (450 g) |
Manufacturer Warranty | 2 years meter and probe; 1 year Smart Cap™ |