{"product_id":"hanna-hi98713-iso-portable-turbidity-meter","title":"Hanna Portable Turbidity Meter","description":"\u003ch4 class=\"first\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2593\/8322\/files\/Unknown_large.png?v=1515108633\" alt=\"\" style=\"margin-right: 20px; margin-bottom: 1px; float: left;\" width=\"125\" height=\"53\"\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eProduct Code: HI98713\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cbr\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe Hanna HI98713 ISO Portable Turbidity Meter is a high-accuracy portable turbidimeter designed for water-quality testing and environmental monitoring, particularly where accurate measurements at low turbidity levels are important. The HI98713 measures turbidity from 0.00 to 1000 FNU using an infrared optical system that meets and exceeds the requirements of the ISO 7027 method.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe HI98713 uses a ratio nephelometric measurement method with both 90° scattered-light and 180° transmitted-light detectors. An 860 nm infrared LED provides the light source, while the optical system is designed to minimize stray light and color interference for stable, repeatable measurements.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe meter provides normal, continuous, and signal-averaging measurement modes, allowing users to select the appropriate measurement approach for different water samples and field conditions. Automatic range selection provides resolutions of 0.01 FNU, 0.1 FNU, or 1 FNU, depending on the turbidity level.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: Hanna Instruments\u003c\/li\u003e\n\u003cli\u003eModel: HI98713\u003c\/li\u003e\n\u003cli\u003eProduct Type: ISO portable turbidity meter \/ turbidimeter\u003c\/li\u003e\n\u003cli\u003eMeasurement Range: 0.00–1000 FNU\u003c\/li\u003e\n\u003cli\u003eMethod: Ratio nephelometric method with 90° and 180° detectors\u003c\/li\u003e\n\u003cli\u003eISO Standard: Meets and exceeds ISO 7027 requirements\u003c\/li\u003e\n\u003cli\u003eLight Source: 860 nm infrared LED\u003c\/li\u003e\n\u003cli\u003eDetector: Silicon photocell\u003c\/li\u003e\n\u003cli\u003eMeasurement Modes: Normal, continuous, and average\u003c\/li\u003e\n\u003cli\u003eAutomatic range selection\u003c\/li\u003e\n\u003cli\u003eTwo-, three-, or four-point calibration\u003c\/li\u003e\n\u003cli\u003eFast Tracker™ Tag Identification System\u003c\/li\u003e\n\u003cli\u003eGLP data recording\u003c\/li\u003e\n\u003cli\u003eStores up to 200 measurements\u003c\/li\u003e\n\u003cli\u003eUSB and RS232 data connectivity\u003c\/li\u003e\n\u003cli\u003eBacklit graphic LCD\u003c\/li\u003e\n\u003cli\u003eSupplied with AMCO AEPA-1 primary turbidity standards\u003c\/li\u003e\n\u003cli\u003eRugged carrying case included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable id=\"product-attribute-specs-table\" class=\"data table additional-attributes\" style=\"width: 541px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eSKU\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003eHI98713-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eProduct Name\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003eTurbidity (ISO) Portable Meter - HI98713\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eQuote Required\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eTurbidity Range\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003e0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eTurbidity Resolution\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003e0.01; 0.1; 1 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eTurbidity Accuracy\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003e±2% of reading plus 0.1 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eTurbidity Repeatability\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003e±1% of reading or 0.01 FNU, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eTurbidity Stray Light\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003e\u0026lt; 0.1 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eTurbidity Calibration\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003etwo, three, or four-point calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eTurbidity Measuring Method\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003eratio nephelometric method (90° \u0026amp; 180°). Adaptation of ISO 7027\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eTurbidity Measuring Modes\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003enormal, average, continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eTurbidity Light Source\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003e860 nm infrared LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eTurbidity Light Detector\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003eSilicon Photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eLogging Memory\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003e200 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eConnectivity\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003eUSB or RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eAutomatic Shut-Off\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003eauto-off after 15 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003e60 x 90 mm LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eBattery Type\/Life\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003e4 (1.5V) AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003e4 (1.5V) AA batteries \/ AC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003e0 to 50°C (32 to 122°F), RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003e224 x 87 x 77 mm (8.8 x 3.4 x 3.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003e512 g (18 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\" style=\"width: 134.0441131591797px;\"\u003eOrdering Information\u003c\/th\u003e\n\u003ctd class=\"col data\" style=\"width: 391.9558868408203px;\"\u003eHI98713 is supplied with sample cuvettes and caps (5), HI98713-11 calibration cuvettes, silicone oil, cuvette wiping cloth, batteries, AC adapter, instructions, and rugged carrying case.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003eThis \u003c\/span\u003e\u003cspan\u003eHI98713 \u003c\/span\u003e\u003cspan\u003ePortable Turbidimeter is supplied complete with:\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 3\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003e• Five Sample Cuvettes and Caps\u003cbr\u003e• Four Calibration Cuvettes (\u003c\/span\u003e\u003cspan\u003eHI98713-11\u003c\/span\u003e\u003cspan\u003e) • Silicone Oil (\u003c\/span\u003e\u003cspan\u003eHI93703-58\u003c\/span\u003e\u003cspan\u003e)\u003cbr\u003e• Tissue for wiping the cuvettes\u003cbr\u003e• Five Tag holders with Tags (\u003c\/span\u003e\u003cspan\u003eHI920005\u003c\/span\u003e\u003cspan\u003e) • Batteries (4 pcs.)\u003cbr\u003e• AC Adapter\u003cbr\u003e• Instruction Manual\u003cbr\u003e• Quick Reference Guide\u003cbr\u003e• Instrument Quality Certificate\u003cbr\u003e• Rigid carrying case\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":42770624905347,"sku":"HI98713","price":1732.5,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2593\/8322\/products\/hi98713_1_1.jpg?v=1659045456","url":"https:\/\/dynamicaquasupply.com\/products\/hanna-hi98713-iso-portable-turbidity-meter","provider":"Dynamic  Aqua-Supply","version":"1.0","type":"link"}